Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Eur Radiol ; 34(3): 2084-2092, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658141

RESUMO

OBJECTIVES: To develop a deep learning-based method for contrast-enhanced breast lesion detection in ultrafast screening MRI. MATERIALS AND METHODS: A total of 837 breast MRI exams of 488 consecutive patients were included. Lesion's location was independently annotated in the maximum intensity projection (MIP) image of the last time-resolved angiography with stochastic trajectories (TWIST) sequence for each individual breast, resulting in 265 lesions (190 benign, 75 malignant) in 163 breasts (133 women). YOLOv5 models were fine-tuned using training sets containing the same number of MIP images with and without lesions. A long short-term memory (LSTM) network was employed to help reduce false positive predictions. The integrated system was then evaluated on test sets containing enriched uninvolved breasts during cross-validation to mimic the performance in a screening scenario. RESULTS: In five-fold cross-validation, the YOLOv5x model showed a sensitivity of 0.95, 0.97, 0.98, and 0.99, with 0.125, 0.25, 0.5, and 1 false positive per breast, respectively. The LSTM network reduced 15.5% of the false positive prediction from the YOLO model, and the positive predictive value was increased from 0.22 to 0.25. CONCLUSIONS: A fine-tuned YOLOv5x model can detect breast lesions on ultrafast MRI with high sensitivity in a screening population, and the output of the model could be further refined by an LSTM network to reduce the amount of false positive predictions. CLINICAL RELEVANCE STATEMENT: The proposed integrated system would make the ultrafast MRI screening process more effective by assisting radiologists in prioritizing suspicious examinations and supporting the diagnostic workup. KEY POINTS: • Deep convolutional neural networks could be utilized to automatically pinpoint breast lesions in screening MRI with high sensitivity. • False positive predictions significantly increased when the detection models were tested on highly unbalanced test sets with more normal scans. • Dynamic enhancement patterns of breast lesions during contrast inflow learned by the long short-term memory networks helped to reduce false positive predictions.


Assuntos
Neoplasias da Mama , Meios de Contraste , Feminino , Humanos , Meios de Contraste/farmacologia , Mama/patologia , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Tempo , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia
2.
Eur Radiol ; 34(3): 1877-1892, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37646809

RESUMO

OBJECTIVES: Multiple lung cancer screening studies reported the performance of Lung CT Screening Reporting and Data System (Lung-RADS), but none systematically evaluated its performance across different populations. This systematic review and meta-analysis aimed to evaluate the performance of Lung-RADS (versions 1.0 and 1.1) for detecting lung cancer in different populations. METHODS: We performed literature searches in PubMed, Web of Science, Cochrane Library, and Embase databases on October 21, 2022, for studies that evaluated the accuracy of Lung-RADS in lung cancer screening. A bivariate random-effects model was used to estimate pooled sensitivity and specificity, and heterogeneity was explored in stratified and meta-regression analyses. RESULTS: A total of 31 studies with 104,224 participants were included. For version 1.0 (27 studies, 95,413 individuals), pooled sensitivity was 0.96 (95% confidence interval [CI]: 0.90-0.99) and pooled specificity was 0.90 (95% CI: 0.87-0.92). Studies in high-risk populations showed higher sensitivity (0.98 [95% CI: 0.92-0.99] vs. 0.84 [95% CI: 0.50-0.96]) and lower specificity (0.87 [95% CI: 0.85-0.88] vs. 0.95 (95% CI: 0.92-0.97]) than studies in general populations. Non-Asian studies tended toward higher sensitivity (0.97 [95% CI: 0.91-0.99] vs. 0.91 [95% CI: 0.67-0.98]) and lower specificity (0.88 [95% CI: 0.85-0.90] vs. 0.93 [95% CI: 0.88-0.96]) than Asian studies. For version 1.1 (4 studies, 8811 individuals), pooled sensitivity was 0.91 (95% CI: 0.83-0.96) and specificity was 0.81 (95% CI: 0.67-0.90). CONCLUSION: Among studies using Lung-RADS version 1.0, considerable heterogeneity in sensitivity and specificity was noted, explained by population type (high risk vs. general), population area (Asia vs. non-Asia), and cancer prevalence. CLINICAL RELEVANCE STATEMENT: Meta-regression of lung cancer screening studies using Lung-RADS version 1.0 showed considerable heterogeneity in sensitivity and specificity, explained by the different target populations, including high-risk versus general populations, Asian versus non-Asian populations, and populations with different lung cancer prevalence. KEY POINTS: • High-risk population studies showed higher sensitivity and lower specificity compared with studies performed in general populations by using Lung-RADS version 1.0. • In non-Asian studies, the diagnostic performance of Lung-RADS version 1.0 tended to be better than in Asian studies. • There are limited studies on the performance of Lung-RADS version 1.1, and evidence is lacking for Asian populations.


Assuntos
Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Detecção Precoce de Câncer , Pulmão/diagnóstico por imagem , Sensibilidade e Especificidade
3.
Eur Radiol ; 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38008743

RESUMO

OBJECTIVES: To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density. METHODS: Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D). RESULTS: Image quality of DWI was higher in the case of increased breast density, with good scores (score 3-5) in 85.9% (D) and 88.4% (C), compared to 61.6% (B) and 53.5% (A). Overall image quality of DWI was in favor of dense breasts (C/D), with an area under the VGC curve of 0.659 (p < 0.001). Quality of DWI and DCE-T1 fat suppression increased with higher breast density, with good scores (score 3-5) for 86.9% and 45.7% of density D, and 90.2% and 42.9% of density C cases, compared to 76.0% and 33.6% for density B and 54.7% and 29.6% for density A (DWI and DCE-T1 respectively). CONCLUSIONS: Dense breasts show excellent fat suppression and substantially higher image quality in DWI images compared with non-dense breasts. These results support the setup of studies exploring DWI-based MR imaging without IV contrast for additional screening of women with dense breasts. CLINICAL RELEVANCE STATEMENT: Our findings demonstrate that image quality of DWI is robust in women with an increased amount of fibroglandular tissue, technically supporting the feasibility of exploring applications such as screening of women with mammographically dense breasts. KEY POINTS: • Image and fat suppression quality of diffusion-weighted imaging are dependent on the amount of fibroglandular tissue (FGT) which is closely connected to breast density. • Fat suppression quality in diffusion-weighted imaging of the breast is best in women with a high amount of fibroglandular tissue. • High image quality of diffusion-weighted imaging in women with a high amount of FGT in MRI supports that the technical feasibility of DWI can be explored in the additional screening of women with mammographically dense breasts.

4.
J Magn Reson Imaging ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37846440

RESUMO

BACKGROUND: Accurate breast density evaluation allows for more precise risk estimation but suffers from high inter-observer variability. PURPOSE: To evaluate the feasibility of reducing inter-observer variability of breast density assessment through artificial intelligence (AI) assisted interpretation. STUDY TYPE: Retrospective. POPULATION: Six hundred and twenty-one patients without breast prosthesis or reconstructions were randomly divided into training (N = 377), validation (N = 98), and independent test (N = 146) datasets. FIELD STRENGTH/SEQUENCE: 1.5 T and 3.0 T; T1-weighted spectral attenuated inversion recovery. ASSESSMENT: Five radiologists independently assessed each scan in the independent test set to establish the inter-observer variability baseline and to reach a reference standard. Deep learning and three radiomics models were developed for three classification tasks: (i) four Breast Imaging-Reporting and Data System (BI-RADS) breast composition categories (A-D), (ii) dense (categories C, D) vs. non-dense (categories A, B), and (iii) extremely dense (category D) vs. moderately dense (categories A-C). The models were tested against the reference standard on the independent test set. AI-assisted interpretation was performed by majority voting between the models and each radiologist's assessment. STATISTICAL TESTS: Inter-observer variability was assessed using linear-weighted kappa (κ) statistics. Kappa statistics, accuracy, and area under the receiver operating characteristic curve (AUC) were used to assess models against reference standard. RESULTS: In the independent test set, five readers showed an overall substantial agreement on tasks (i) and (ii), but moderate agreement for task (iii). The best-performing model showed substantial agreement with reference standard for tasks (i) and (ii), but moderate agreement for task (iii). With the assistance of the AI models, almost perfect inter-observer variability was obtained for tasks (i) (mean κ = 0.86), (ii) (mean κ = 0.94), and (iii) (mean κ = 0.94). DATA CONCLUSION: Deep learning and radiomics models have the potential to help reduce inter-observer variability of breast density assessment. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.

5.
Radiology ; 307(4): e221922, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36975820

RESUMO

Background Several single-center studies found that high contralateral parenchymal enhancement (CPE) at breast MRI was associated with improved long-term survival in patients with estrogen receptor (ER)-positive and human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Due to varying sample sizes, population characteristics, and follow-up times, consensus of the association is currently lacking. Purpose To confirm whether CPE is associated with long-term survival in a large multicenter retrospective cohort, and to investigate if CPE is associated with endocrine therapy effectiveness. Materials and Methods This multicenter observational cohort included women with unilateral ER-positive HER2-negative breast cancer (tumor size ≤50 mm and ≤three positive lymph nodes) who underwent MRI from January 2005 to December 2010. Overall survival (OS), recurrence-free survival (RFS), and distant RFS (DRFS) were assessed. Kaplan-Meier analysis was performed to investigate differences in absolute risk after 10 years, stratified according to CPE tertile. Multivariable Cox proportional hazards regression analysis was performed to investigate whether CPE was associated with prognosis and endocrine therapy effectiveness. Results Overall, 1432 women (median age, 54 years [IQR, 47-63 years]) were included from 10 centers. Differences in absolute OS after 10 years were stratified according to CPE tertile as follows: 88.5% (95% CI: 88.1, 89.1) in tertile 1, 85.8% (95% CI: 85.2, 86.3) in tertile 2, and 85.9% (95% CI: 85.4, 86.4) in tertile 3. CPE was independently associated with OS, with a hazard ratio (HR) of 1.17 (95% CI: 1.0, 1.36; P = .047), but was not associated with RFS (HR, 1.11; P = .16) or DRFS (HR, 1.11; P = .19). The effect of endocrine therapy on survival could not be accurately assessed; therefore, the association between endocrine therapy efficacy and CPE could not reliably be estimated. Conclusion High contralateral parenchymal enhancement was associated with a marginally decreased overall survival in patients with estrogen receptor-positive and human epidermal growth factor receptor 2-negative breast cancer, but was not associated with recurrence-free survival (RFS) or distant RFS. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Honda and Iima in this issue.


Assuntos
Neoplasias da Mama , Neoplasias de Mama Triplo Negativas , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/metabolismo , Receptores de Estrogênio , Estudos Retrospectivos , Neoplasias de Mama Triplo Negativas/patologia , Mama/diagnóstico por imagem , Mama/metabolismo , Prognóstico , Receptor ErbB-2/metabolismo , Imageamento por Ressonância Magnética/métodos , Intervalo Livre de Doença , Recidiva Local de Neoplasia/patologia
6.
Eur J Radiol ; 160: 110709, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36731401

RESUMO

PURPOSE: The Fleischner society criteria are global criteria to visually evaluate and classify pulmonary emphysema on CT. It may group heterogeneous disease severity within the same category, potentially obscuring clinically relevant differences in emphysema severity. This proof-of-concept study proposes to split emphysema into more categories and to assess each lobe separately, and applies this to two general population-based cohort samples to assess what information such an extension adds. METHOD: From a consecutive sample in two general population-based cohorts with low-dose chest CT, 117 participants with more than a trace of emphysema were included. Two independent readers performed an extended per-lobe classification and assessed overall severity semi-quantitatively. An emphysema sum score was determined by adding the severity score of all lobes. Inter-reader agreement was quantified with Krippendorff Alpha. RESULTS: Based on Fleischner society criteria, 69 cases had mild to severe centrilobular emphysema, and 90 cases had mild or moderate paraseptal emphysema (42 had both types of emphysema). The emphysema sum score was significantly different between mild (10.7 ± 4.3, range 2-22), moderate (20.1 ± 3.1, range: 15-24), and severe emphysema (23.6 ± 3.4, range: 17-28, p < 0.001), but ranges showed significant overlap. Inter-reader agreement for the extended classification and sum score was substantial (alpha 0.79 and 0.85, respectively). Distribution was homogenous across lobes in never-smokers, yet heterogenous in current smokers, with upper-lobe predominance. CONCLUSIONS: The proposed emphysema evaluation method adds information to the original Fleischner society classification. Individuals in the same Fleischner category have diverse emphysema sum scores, and lobar emphysema distribution differs between smoking groups.


Assuntos
Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Enfisema Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Enfisema/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Fumar/epidemiologia
7.
MAGMA ; 36(4): 613-619, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36527516

RESUMO

OBJECTIVE: Reduced FOV-diffusion-weighted imaging (rFOV-DWI) allows for acquisition of a tissue region without back-folding, and may have better fat suppression than conventional DWI imaging (c-DWI). The aim was to compare the ADCs obtained with c-DWI bilateral-breast imaging with single-breast rFOV-DWI. MATERIALS AND METHODS: Breasts of 38 patients were scanned at 3 T. The mean ADC values obtained for 38 lesions, and fibro-glandular (N = 35) and adipose (N = 38) tissue ROIs were compared between c-DWI and higher-resolution rFOV-DWI (Wilcoxon rank test). Also, the ADCs were compared between the two acquisitions for an oil-only phantom and a combined water/oil phantom. Furthermore, ghost artifacts were assessed. RESULTS: No significant difference in mean ADC was found between the acquisitions for lesions (c-DWI: 1.08 × 10-3 mm2/s, rFOV-DWI: 1.13 × 10-3 mm2/s) and fibro-glandular tissue. For adipose tissue, the ADC using rFOV-DWI (0.31 × 10-3 mm2/s) was significantly higher than c-DWI (0.16 × 10-3 mm2/s). For the oil-only phantom, no difference in ADC was found. However, for the water/oil phantom, the ADC of oil was significantly higher with rFOV-DWI compared to c-DWI. DISCUSSION: Although ghost artifacts were observed for both acquisitions, they appeared to have a greater impact for rFOV-DWI. However, no differences in mean lesions' ADC values were found, and therefore this study suggests that rFOV can be used diagnostically for single-breast DWI imaging.


Assuntos
Mama , Imagem de Difusão por Ressonância Magnética , Humanos , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Imagens de Fantasmas , Artefatos , Imagem Ecoplanar/métodos , Reprodutibilidade dos Testes
8.
Eur Radiol ; 32(12): 8162-8170, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35678862

RESUMO

OBJECTIVES: This study aimed to evaluate the association between visual emphysema and the presence of lung nodules, and Lung-RADS category with low-dose CT (LDCT). METHODS: Baseline LDCT scans of 1162 participants from a lung cancer screening study (Nelcin-B3) performed in a Chinese general population were included. The presence, subtypes, and severity of emphysema (at least trace) were visually assessed by one radiologist. The presence, size, and classification of non-calcified lung nodules (≥ 30 mm3) and Lung-RADS category were independently assessed by another two radiologists. Multivariable logistic regression and stratified analyses were performed to estimate the association between emphysema and lung nodules, Lung-RADS category, after adjusting for age, sex, BMI, smoking status, pack-years, and passive smoking. RESULTS: Emphysema and lung nodules were observed in 674 (58.0%) and 424 (36.5%) participants, respectively. Participants with emphysema had a 71% increased risk of having lung nodules (adjusted odds ratios, aOR: 1.71, 95% CI: 1.26-2.31) and 70% increased risk of positive Lung-RADS category (aOR: 1.70, 95% CI: 1.09-2.66) than those without emphysema. Participants with paraseptal emphysema (n = 47, 4.0%) were at a higher risk for lung nodules than those with centrilobular emphysema (CLE) (aOR: 2.43, 95% CI: 1.32-4.50 and aOR: 1.60, 95% CI: 1.23-2.09, respectively). Only CLE was associated with positive Lung-RADS category (p = 0.02). CLE severity was related to a higher risk of lung nodules (ranges aOR: 1.44-2.61, overall p < 0.01). CONCLUSION: In a Chinese general population, visual emphysema based on LDCT is independently related to the presence of lung nodules (≥ 30 mm3) and specifically CLE subtype is related to positive Lung-RADS category. The risk of lung nodules increases with CLE severity. KEY POINTS: • Participants with emphysema had an increased risk of having lung nodules, especially smokers. • Participants with PSE were at a higher risk for lung nodules than those with CLE, but nodules in participants with CLE had a higher risk of positive Lung-RADS category. • The risk of lung nodules increases with CLE severity.


Assuntos
Enfisema , Neoplasias Pulmonares , Lesões Pré-Cancerosas , Enfisema Pulmonar , Humanos , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/epidemiologia , Enfisema Pulmonar/etiologia , Tomografia Computadorizada por Raios X/efeitos adversos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/complicações , Detecção Precoce de Câncer/efeitos adversos , Pulmão/diagnóstico por imagem , Enfisema/diagnóstico por imagem , Enfisema/epidemiologia , China
9.
Eur Radiol ; 32(12): 8706-8715, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35614363

RESUMO

OBJECTIVES: To investigate the feasibility of automatically identifying normal scans in ultrafast breast MRI with artificial intelligence (AI) to increase efficiency and reduce workload. METHODS: In this retrospective analysis, 837 breast MRI examinations performed on 438 women from April 2016 to October 2019 were included. The left and right breasts in each examination were labelled normal (without suspicious lesions) or abnormal (with suspicious lesions) based on final interpretation. Maximum intensity projection (MIP) images of each breast were then used to train a deep learning model. A high sensitivity threshold was calculated based on the detection trade - off (DET) curve on the validation set. The performance of the model was evaluated by receiver operating characteristic analysis of the independent test set. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with the high sensitivity threshold were calculated. RESULTS: The independent test set consisted of 178 examinations of 149 patients (mean age, 44 years ± 14 [standard deviation]). The trained model achieved an AUC of 0.81 (95% CI: 0.75-0.88) on the independent test set. Applying a threshold of 0.25 yielded a sensitivity of 98% (95% CI: 90%; 100%), an NPV of 98% (95% CI: 89%; 100%), a workload reduction of 15.7%, and a scan time reduction of 16.6%. CONCLUSION: This deep learning model has a high potential to help identify normal scans in ultrafast breast MRI and thereby reduce radiologists' workload and scan time. KEY POINTS: • Deep learning in TWIST may eliminate the necessity of additional sequences for identifying normal breasts during MRI screening. • Workload and scanning time reductions of 15.7% and 16.6%, respectively, could be achieved with the cost of 1 (1 of 55) false negative prediction.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Humanos , Feminino , Adulto , Inteligência Artificial , Estudos Retrospectivos , Mama/diagnóstico por imagem , Mama/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia
10.
Cancer Epidemiol Biomarkers Prev ; 31(7): 1442-1449, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35534234

RESUMO

BACKGROUND: The relationship between smoking, airflow limitation, and lung cancer occurrence is unclear. This study aims to evaluate the relationship between airflow limitation and lung cancer, and the effect modification by smoking status. METHODS: We included participants with spirometry data from Lifelines, a population-based cohort study from the Northern Netherlands. Airflow limitation was defined as FEV1/FVC ratio < 0.7. The presence of pathology-confirmed primary lung cancer during a median follow-up of 9.5 years was collected. The Cox regression model was used and hazard ratios (HR) with 95% confidence interval (95% CI) were reported. Adjusted confounders included age, sex, educational level, smoking, passive smoking, asthma status and asbestos exposure. The effect modification by smoking status was investigated by estimating the relative excess risk due to interaction (RERI) and the ratio of HRs with 95% CI. RESULTS: Out of 98,630 participants, 14,200 (14.4%) had airflow limitation. In participants with and without airflow limitation, lung cancer incidence was 0.8% and 0.2%, respectively. The adjusted HR between airflow limitation and lung cancer risk was 1.7 (1.4-2.3). The association between airflow limitation and lung cancer differed by smoking status [former smokers: 2.1 (1.4-3.2), current smokers: 2.2 (1.5-3.2)] and never smokers [0.9 (0.4-2.1)]. The RERI and ratio of HRs was 2.1 (0.7-3.4) and 2.5 (1.0-6.5) for former smokers, and 4.6 (95% CI, 1.8-7.4) and 2.5 (95% CI, 1.0-6.3) for current smokers, respectively. CONCLUSIONS: Airflow limitation increases lung cancer risk and this association is modified by smoking status. IMPACT: Ever smokers with airflow limitation are an important target group for the prevention of lung cancer.


Assuntos
Neoplasias Pulmonares , Doença Pulmonar Obstrutiva Crônica , Estudos de Coortes , Humanos , Pulmão , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/etiologia , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Fatores de Risco , Fumantes
11.
Radiology ; 304(2): 322-330, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35503012

RESUMO

Background Given the different methods of assessing emphysema, controversy exists as to whether it is associated with lung cancer. Purpose To perform a systematic review and meta-analysis of the association between chest CT-defined emphysema and the presence of lung cancer. Materials and Methods The PubMed, Embase, and Cochrane databases were searched up to July 15, 2021, to identify studies on the association between emphysema assessed visually or quantitatively with CT and lung cancer. Associations were determined by emphysema severity (trace, mild, or moderate to severe, assessed visually and quantitatively) and subtype (centrilobular and paraseptal, assessed visually). Overall and stratified pooled odds ratios (ORs) with their 95% CIs were obtained. Results Of the 3343 screened studies, 21 studies (107 082 patients) with 26 subsets were included. The overall pooled ORs for lung cancer given the presence of emphysema were 2.3 (95% CI: 2.0, 2.6; I2 = 35%; 19 subsets) and 1.02 (95% CI: 1.01, 1.02; six subsets) per 1% increase in low attenuation area. Studies with visual (pooled OR, 2.3; 95% CI: 1.9, 2.6; I2 = 48%; 12 subsets) and quantitative (pooled OR, 2.2; 95% CI: 1.8, 2.8; I2 = 3.7%; eight subsets) assessments yielded comparable results for the dichotomous assessment. Based on six studies (1716 patients), the pooled ORs for lung cancer increased with emphysema severity and were higher for visual assessment (2.5, 3.7, and 4.5 for trace, mild, and moderate to severe, respectively) than for quantitative assessment (1.9, 2.2, and 2.5) based on point estimates. Compared with no emphysema, only centrilobular emphysema (three studies) was associated with lung cancer (pooled OR, 2.2; 95% CI: 1.5, 3.2; P < .001). Conclusion Both visual and quantitative CT assessments of emphysema were associated with a higher odds of lung cancer, which also increased with emphysema severity. Regarding subtype, only centrilobular emphysema was significantly associated with lung cancer. Clinical trial registration no. CRD42021262163 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Hunsaker in this issue.


Assuntos
Enfisema , Neoplasias Pulmonares , Enfisema Pulmonar , Humanos , Pulmão , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico por imagem , Razão de Chances , Enfisema Pulmonar/complicações , Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
12.
Cancers (Basel) ; 14(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35454949

RESUMO

PURPOSE: To investigate the feasibility of using deep learning methods to differentiate benign from malignant breast lesions in ultrafast MRI with both temporal and spatial information. METHODS: A total of 173 single breasts of 122 women (151 examinations) with lesions above 5 mm were retrospectively included. A total of 109 out of 173 lesions were benign. Maximum intensity projection (MIP) images were generated from each of the 14 contrast-enhanced T1-weighted acquisitions in the ultrafast MRI scan. A 2D convolutional neural network (CNN) and a long short-term memory (LSTM) network were employed to extract morphological and temporal features, respectively. The 2D CNN model was trained with the MIPs from the last four acquisitions to ensure the visibility of the lesions, while the LSTM model took MIPs of an entire scan as input. The performance of each model and their combination were evaluated with 100-times repeated stratified four-fold cross-validation. Those models were then compared with models developed with standard DCE-MRI which followed the same data split. RESULTS: In the differentiation between benign and malignant lesions, the ultrafast MRI-based 2D CNN achieved a mean AUC of 0.81 ± 0.06, and the LSTM network achieved a mean AUC of 0.78 ± 0.07; their combination showed a mean AUC of 0.83 ± 0.06 in the cross-validation. The mean AUC values were significantly higher for ultrafast MRI-based models than standard DCE-MRI-based models. CONCLUSION: Deep learning models developed with ultrafast breast MRI achieved higher performances than standard DCE-MRI for malignancy discrimination. The improved AUC values of the combined models indicate an added value of temporal information extracted by the LSTM model in breast lesion characterization.

13.
Lung Cancer ; 165: 133-140, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35123156

RESUMO

OBJECTIVE: To evaluate performance of AI as a standalone reader in ultra-low-dose CT lung cancer baseline screening, and compare it to that of experienced radiologists. METHODS: 283 participants who underwent a baseline ultra-LDCT scan in Moscow Lung Cancer Screening, between February 2017-2018, and had at least one solid lung nodule, were included. Volumetric nodule measurements were performed by five experienced blinded radiologists, and independently assessed using an AI lung cancer screening prototype (AVIEW LCS, v1.0.34, Coreline Soft, Co. ltd, Seoul, Korea) to automatically detect, measure, and classify solid nodules. Discrepancies were stratified into two groups: positive-misclassification (PM); nodule classified by the reader as a NELSON-plus /EUPS-indeterminate/positive nodule, which at the reference consensus read was < 100 mm3, and negative-misclassification (NM); nodule classified as a NELSON-plus /EUPS-negative nodule, which at consensus read was ≥ 100 mm3. RESULTS: 1149 nodules with a solid-component were detected, of which 878 were classified as solid nodules. For the largest solid nodule per participant (n = 283); 61 [21.6 %; 53 PM, 8 NM] discrepancies were reported for AI as a standalone reader, compared to 43 [15.1 %; 22 PM, 21 NM], 36 [12.7 %; 25 PM, 11 NM], 29 [10.2 %; 25 PM, 4 NM], 28 [9.9 %; 6 PM, 22 NM], and 50 [17.7 %; 15 PM, 35 NM] discrepancies for readers 1, 2, 3, 4, and 5 respectively. CONCLUSION: Our results suggest that through the use of AI as an impartial reader in baseline lung cancer screening, negative-misclassification results could exceed that of four out of five experienced radiologists, and radiologists' workload could be drastically diminished by up to 86.7%.

15.
Eur J Radiol ; 146: 110068, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34871936

RESUMO

OBJECTIVE: To evaluate the performance of a deep learning-based computer-aided detection (DL-CAD) system in a Chinese low-dose CT (LDCT) lung cancer screening program. MATERIALS AND METHODS: One-hundred-and-eighty individuals with a lung nodule on their baseline LDCT lung cancer screening scan were randomly mixed with screenees without nodules in a 1:1 ratio (total: 360 individuals). All scans were assessed by double reading and subsequently processed by an academic DL-CAD system. The findings of double reading and the DL-CAD system were then evaluated by two senior radiologists to derive the reference standard. The detection performance was evaluated by the Free Response Operating Characteristic curve, sensitivity and false-positive (FP) rate. The senior radiologists categorized nodules according to nodule diameter, type (solid, part-solid, non-solid) and Lung-RADS. RESULTS: The reference standard consisted of 262 nodules ≥ 4 mm in 196 individuals; 359 findings were considered false positives. The DL-CAD system achieved a sensitivity of 90.1% with 1.0 FP/scan for detection of lung nodules regardless of size or type, whereas double reading had a sensitivity of 76.0% with 0.04 FP/scan (P = 0.001). The sensitivity for detection of nodules ≥ 4 - ≤ 6 mm was significantly higher with DL-CAD than with double reading (86.3% vs. 58.9% respectively; P = 0.001). Sixty-three nodules were only identified by the DL-CAD system, and 27 nodules only found by double reading. The DL-CAD system reached similar performance compared to double reading in Lung-RADS 3 (94.3% vs. 90.0%, P = 0.549) and Lung-RADS 4 nodules (100.0% vs. 97.0%, P = 1.000), but showed a higher sensitivity in Lung-RADS 2 (86.2% vs. 65.4%, P < 0.001). CONCLUSIONS: The DL-CAD system can accurately detect pulmonary nodules on LDCT, with an acceptable false-positive rate of 1 nodule per scan and has higher detection performance than double reading. This DL-CAD system may assist radiologists in nodule detection in LDCT lung cancer screening.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Nódulo Pulmonar Solitário , China/epidemiologia , Detecção Precoce de Câncer , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X
16.
Breast ; 61: 58-65, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34915447

RESUMO

INTRODUCTION: Magnetic resonance imaging (MRI) has shown the potential to improve the screening effectiveness among women with dense breasts. The introduction of fast abbreviated protocols (AP) makes MRI more feasible to be used in a general population. We aimed to investigate the cost-effectiveness of AP-MRI in women with dense breasts (heterogeneously/extremely dense) in a population-based screening program. METHODS: A previously validated model (SiMRiSc) was applied, with parameters updated for women with dense breasts. Breast density was assumed to decrease with increased age. The base scenarios included six biennial AP-MRI strategies, with biennial mammography from age 50-74 as reference. Fourteen alternative scenarios were performed by varying screening interval (triennial and quadrennial) and by applying a combined strategy of mammography and AP-MRI. A 3% discount rate for both costs and life years gained (LYG) was applied. Model robustness was evaluated using univariate and probabilistic sensitivity analyses. RESULTS: The six biennial AP-MRI strategies ranged from 132 to 562 LYG per 10,000 women, where more frequent application of AP-MRI was related to higher LYG. The optimal strategy was biennial AP-MRI screening from age 50-65 for only women with extremely dense breasts, producing an incremental cost-effectiveness ratio of € 18,201/LYG. At a threshold of € 20,000/LYG, the probability that the optimal strategy was cost-effective was 79%. CONCLUSION: Population-based biennial breast cancer screening with AP-MRI from age 50-65 for women with extremely dense breasts might be a cost-effective alternative to mammography, but is not an option for women with heterogeneously dense breasts.


Assuntos
Densidade da Mama , Neoplasias da Mama , Idoso , Neoplasias da Mama/diagnóstico por imagem , Análise Custo-Benefício , Detecção Precoce de Câncer , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia , Programas de Rastreamento , Pessoa de Meia-Idade
17.
Eur J Radiol ; 144: 109988, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34695695

RESUMO

OBJECTIVE: To evaluate the efficiency of low-dose computed tomography (LDCT) screening for lung cancer in China by analyzing the baseline results of a community-based screening study accompanied with a meta-analysis. METHODS: A first round of community-based lung cancer screening with LDCT was conducted in Tianjin, China, and a systematic literature search was performed to identify LDCT screening and registry-based clinical studies for lung cancer in China. Baseline results in the community-based screening study were described by participant risk level and the lung cancer detection rate was compared with the pooled rate among the screening studies. The percentage of patients per stage was compared between the community-based study and screening and clinical studies. RESULTS: In the community-based study, 5523 participants (43.6% men) underwent LDCT. The lung cancer detection rate was 0.5% (high-risk, 1.2%; low-risk, 0.4%), with stage I disease present in 70.0% (high-risk, 50.0%; low-risk, 83.3%), and the adenocarcinoma present in 84.4% (high-risk, 61.5%; low-risk, 100%). Among all screen-detected lung cancer, women accounted for 8.3% and 66.7% in the high- and low-risk group, respectively. In the screening studies from mainland China, the lung cancer detection rate 0.6% (95 %CI: 0.3%-0.9%) for high-risk populations. The proportions with carcinoma in situ and stage I disease in the screening and clinical studies were 76.4% (95 %CI: 66.3%-85.3%) and 15.2% (95 %CI: 11.8%-18.9%), respectively. CONCLUSIONS: The stage shift of lung cancer due to screening suggests a potential effectiveness of LDCT screening in China. Nearly 70% of screen-detected lung cancers in low-risk populations are identified in women.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , China/epidemiologia , Feminino , Humanos , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/epidemiologia , Masculino , Programas de Rastreamento , Tomografia Computadorizada por Raios X
18.
J Thorac Dis ; 13(7): 4407-4417, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34422367

RESUMO

BACKGROUND: To develop and validate a contrast-enhanced CT based classification tree model for classifying solid lung tumors in clinical patients into malignant or benign. METHODS: Between January 2015 and October 2017, 827 pathologically confirmed solid lung tumors (487 malignant, 340 benign; median size, 27.0 mm, IQR 18.0-39.0 mm) from 827 patients from a dedicated Chinese cancer hospital were identified. Nodules were divided randomly into two groups, a training group (575 cases) and a testing group (252 cases). CT characteristics were collected by two radiologists, and analyzed using a classification and regression tree (CART) model. For validation, we used the decision analysis threshold to evaluate the classification performance of the CART model and radiologist's diagnosis (benign; malignant) in the testing group. RESULTS: Three out of 19 characteristics [margin (smooth; slightly lobulated/lobulated/spiculated), and shape (round/oval; irregular), subjective enhancement (no/uniform enhancement; heterogeneous enhancement)] were automatically generated by the CART model for classifying solid lung tumors. The sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the CART model is 98.5%, 58.1%, 80.6%, 98.6%, 79.8%, and 90.4%, 54.7%, 82.4% 98.5%, 74.2% for the radiologist's diagnosis by using three-threshold decision analysis. CONCLUSIONS: Tumor margin and shape, and subjective tumor enhancement were the most important CT characteristics in the CART model for classifying solid lung tumors as malignant. The CART model had higher discriminatory power than radiologist's diagnosis. The CART model could help radiologists making recommendations regarding follow-up or surgery in clinical patients with a solid lung tumor.

19.
Transl Lung Cancer Res ; 10(2): 1154-1164, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33718053

RESUMO

The aim of this review is to provide clinicians and technicians with an overview of the development of CT protocols in lung cancer screening. CT protocols have evolved from pre-fixed settings in early lung cancer screening studies starting in 2004 towards automatic optimized settings in current international guidelines. The acquisition protocols of large lung cancer screening studies and guidelines are summarized. Radiation dose may vary considerably between CT protocols, but has reduced gradually over the years. Ultra-low dose acquisition can be achieved by applying latest dose reduction techniques. The use of low tube current or tin-filter in combination with iterative reconstruction allow to reduce the radiation dose to a submilliSievert level. However, one should be cautious in reducing the radiation dose to ultra-low dose settings since performed studies lacked generalizability. Continuous efforts are made by international radiology organizations to streamline the CT data acquisition and image quality assurance and to keep track of new developments in CT lung cancer screening. Examples like computer-aided diagnosis and radiomic feature extraction are discussed and current limitations are outlined. Deep learning-based solutions in post-processing of CT images are provided. Finally, future perspectives and recommendations are provided for lung cancer screening CT protocols.

20.
J Thorac Dis ; 13(12): 6855-6865, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35070370

RESUMO

BACKGROUND: Low-dose computed tomography (LDCT) lung cancer screening often refers individuals to unnecessary examinations. This study aims to compare the European Position Statement (EUPS) and National Comprehensive Cancer Network (NCCN) protocols in management of participants at baseline screening round. METHODS: LDCT lung cancer screening was prospectively performed in a Chinese asymptomatic population aged 40-74 years. A total of 1,000 consecutive baseline LDCT scans were read twice independently. All screen-detected lung nodules by the first reader were included. The first reader manually measured the diameter of lung nodules (NCCN protocol), and the second reader semi-automatically measured the volume and diameter (EUPS volume and diameter protocols). The protocols were used to classify the participants into three management groups: next screening round, short-term repeat LDCT scan and referral to a pulmonologist. Groups were compared using Wilcoxon test for paired samples. Number of lung cancers by protocols was provided. RESULTS: Of the 1,000 participants (61.4±6.7 years old), 168 lung nodules in 124 participants were visually detected and manually measured in the first reading, and re-measured semi-automatically. Applying the NCCN protocol, EUPS volume and diameter protocol, the proportion of referrals among all participants was 0.6%, 1.9%, and 1.4%, respectively. The proportion of short-term repeat scans was 4.5%, 9.7% and 4.5%, respectively. Among the 10 lung cancer patients, one would have been diagnosed earlier if the EUPS volume protocol would have been followed. CONCLUSIONS: In a first round screening in a Chinese general population, the lower threshold for referral in the EUPS protocol as compared to the NCCN protocol, leads to more referrals to a pulmonologist, with the potential of earlier cancer diagnosis. The EUPS volume protocol recommends fewer participants to short-term repeat LDCT scan than the EUPS diameter protocol. Follow-up studies should show the impact of both protocols on (interval) cancer diagnosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...